Ion Chromatograph-Full Auto Ion Chromatograph Equipment

  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Hunan

  • Validity to:

    Long-term effective

  • Last update:

    2017-12-05 19:44

  • Browse the number:

    218

Send an inquiries

Company Profile

TRYTE TECHNOLOGY (HUNAN) DEVELOPMENT CO., LTD.

By certification [File Integrity]

Contact:Mr. Robin(Mr.)  

Email:

Telephone:

Phone:

Area:Hunan

Address:Hunan

Website: http://lab-instrument.xlmtc8.com/

Product details
TR-TCIC-01 Ion Chromatograph


Features:

Can equipped with anion/ cat ion dual analysis system, single-column anion /cationic double-column dual work way; Can equipped with different types of separator column to analyze inorganic anions, alkali metals, alkaline-earth metals, ammonium ion, iodide ion, sulfion, cryanide ion , organic acid , amino acid and so on; sequential detection methods, fast in analysis, sensitive and excellent in reproduction.

Technical specifications and standards:

Dimension
Length (330mm)×width (415mm)× height (500mm)

working environment
- Temperature: 10~30ºC
- humidity :25~85%
- power:AC220V±10% 50HZ

Testing range

- 10 kinds of anions (F-,Br-,CI-,SO42-,NO3-,NO2-,HPO42- BrO3-,ClO3-,ClO2- ) and 8 kinds of Cations (Li+,Na+,NH4+,K+ ,Ca2+,Mg2+,Sr2+,Ba2+ )can be tested at one time.
- If ampere detector is available, anions( like iodine, sulfur, and cyanide), cations ( like lead, copper, zinc and cadmium), and organic objects can be detected. (Detection limit: I- 5ppb,S2- 5 ppb,CN- 5 ppb,Cu2+0.5 ppb,Zn2+ 1 ppb,Pb2+ 0.2 ppb,Cd2+ 0.1 ppb)

Anions analyze limit: Cl prior to 0.2ppb

Testing time: density testing of F-,Br-,CI-,SO42-,NO3-,NO2-,HPO42- BrO3-,ClO3-,ClO2- within 20 minutes

Repeatability of multi-testing is better than 2%

Configuration:

The detection of anions and cations are time-sharing. When the anions and cations are detected alternately, the chromatographic column need to be switched and more than half an hour is needed for washing the flow system. It is suitable for customers with limited budget and a small number of daily testing samples.

Order

Unit name

Quan-tity

Origin

Notes

1

Column box and thermostat system

1

Puren

 

2

Conductivity detector

1

Puren

 

3

Ampere detector

1

Puren

can detect heavy metals like Cu2 +, Zn2 +, Pb2 +, Cd2 +

4

High-pressure pump

1

Imported from Germany

42Mpa endurable

5

Six-way injection valve

1

Imported from the USA or Japan

Stainless steel, 60Mpa endurable
PEEK, 35 Mpa endurable

6

Flowing pipe

1

Imported originally

 

7

Anion separation column

1

Original Shodex from Japan

Can analyze F- , Br-,CI-, SO42-, NO3-, NO2-, HPO42-, BrO3-, bromate, ClO3-, ClO2- etc. at one time

8

Cathodic protection column

1

Domestic

 

9

Anion automatically renewable Suppressor

1

Puren

automatically recycling with the eluent waste

10

Cation separation column

1

imported

can detect Li+,Na+,NH4+,K+ ,Ca2+,Mg2+,Sr2+,Ba2+ etc. at one time

11

chromatography workstation

1

Puren

 

12

Accessories

1 set

Puren

 

 

2. Configuration of primary hardware

2.1 Conductivity Detector
Precise 5-electrod conductivity detector: main technical performance
5-electrod Conductivity pool: 316 stainless steel ring deactivated electrode, pool size ≤ 1.2ul. With electronic thermostat, temperature accuracy: 5 ~ 50 ºC ± 0.05 ºC
Resolution: not less than 1 / 20000 (≤ 0.025ns)
Baseline noise: less than 0.6% Fs
Baseline drift: less than ± 2.0% Fs
Range: 0 ~ 3500us. Select files with manual and automatic functions.
Output Voltage: 0 ~ 1000mv.
Automatic zero adjustment range:-1000mv ~ +1000 mv.
Suppressor current: 0 ~ 150mA. Increments 1mA, set by the user on the screen.
Can analyze various types of inorganic anions, organic acids, alkali metal, alkaline earth metals, ammonium and quaternary ammonium plasma

2.2 The high-pressure infusion pump
The machine is microprocessor-controlled dual-piston reciprocating pump, equipped on the fluid path with a buffer and pressure sensors which reduce the pump pulse to a minimum level. Advanced sealing technology enables the pump to work at higher pressure.

Pressure range

0-42.0MPa(stainless iron,ceramic-lined, steel lined with titanium)0~35MPa(PEEK)

Flow range

0.001-9.999mL/min

Flow accuracy

RSD<0.1%

Flow error

<±0.5%

Pressure sensor

Pressure display accuracy: 0.1Mpa

Over-pressure protection

When working pressure is above or below the upper limit or lower limit set, the pump will turn itself off and set the alarm

Material of pump and flow path

PEEK,stainless iron,ceramic-lined, steel lined with titanium( up to the user's choice)

Origin

Germany, the USA, China

2.3 Flow system
2.4 Chromatographic column
2.5 Chromatographic column and conductivity pool thermostatic system
2.6 Chromatographic Workstation
2.7Ampere detector: (optional according to customer's requirements, not included in the above quote)

Four kinds of detection methods: DC amps, pulsed amperometric, amperometric, differential pulse voltammetry. By way of flow path or flow injection and the selection of suitable working electrode, the above four methods of measurement can be achieved. Apply to detection of anions (like iodine, sulfur, cyanide), cations( like lead, copper, zinc, cadmium) and organic.

Detection range: 1μg/L-1mg/L
Detection limit: I- 5ppb,S2- 5 ppb,CN- 5 ppb,Cu2+ 0.5 ppb,Zn2+ 1 ppb,Pb2+ 0.2 ppb,Cd2+ 0.1 ppb

3. Instrument peripherals configuration (self-selection by the customer, prices are not included in the above quote)

3.1 Computer
3.1.1 role: to assist the PIC-10-type halogen dedicated tester for data processing
3.1.2 Configuration: Operating System Configuration: OS - Windows 2000/XP
3.1.3 Memory: 512M
3.1.4 Display Monitor: 17 "SVGA LCD
3.1.5 Hard disk HD: 80G or more
3.1.6 CD-ROM DVD-ROM: 24X or more
3.1.7 CPU: P4 2.6

3.2 Color Inkjet Printers
3.2.1 Role: output the results from the computer.

4. Test spectra:

Order

Remaining time

Name

Density

Peak area

Peak Seperation

Theoretical plate number

1

6.207

F

1.0000

532199

8.26

4492

2

9.521

BrO3

5.0000

343348

2.34

8232

3

10.501

Cl

2.0000

736985

6.21

10849

4

13.323

NO2

4.0000

791700

7.66

11735

5

17.483

Br

6.0000

933260

5.29

14697

6

20.848

NO3

6.0000

1221725

7.88

15243

7

26.863

HPO4

8.0000

532169

5.30

16871

8

31.571

SO4

8.0000

2139946

0.00

18808

Total 45.0000 7231332 



 

TR-TCIC-01 Ion Chromatograph (Daul System)

Features:

Can equipped with anion/ cat ion dual analysis system, single-column anion /cationic double-column dual work way; Can equipped with different types of separator column to analyze inorganic anions, alkali metals, alkaline-earth metals, ammonium ion, iodide ion, sulfion, cryanide ion , organic acid , amino acid and so on; sequential detection methods, fast in analysis, sensitive and excellent in reproduction.

Technical specifications and standards:

Dimension
Length (330mm)×width (415mm)× height (500mm)

working environment
- Temperature: 10~30ºC
- humidity: 25~85%
- power: AC220V±10% 50HZ

Testing range

- 10 kinds of anions (F-,Br-,CI-,SO42-,NO3-,NO2-,HPO42- BrO3-,ClO3-,ClO2- ) and 8 kinds of Cations (Li+,Na+,NH4+,K+ ,Ca2+,Mg2+,Sr2+,Ba2+ )can be tested at one time.
- If ampere detector is available, anions( like iodine, sulfur, and cyanide), cations ( like lead, copper, zinc and cadmium), and organic objects can be detected. (Detection limit: I- 5ppb,S2- 5 ppb,CN- 5 ppb,Cu2+0.5 ppb,Zn2+ 1 ppb,Pb2+ 0.2 ppb,Cd2+ 0.1 ppb)

Anions analyze limit: Cl prior to 0.2ppb

Testing time: density testing of F-,Br-,CI-,SO42-,NO3-,NO2-,HPO42- BrO3-,ClO3-,ClO2- within 20 minutes

Repeatability of multi-testing is better than 2%

Configuration:

Anions and cations can be detected simultaneously sampling. There is no need for switching of chromatographic columns or washing of flow system. This configuration is suitable for customers with sufficient funds and a large number of testing samples.

Order

Unit name

Quantity

Origin

Notes

1

Conductivity detector

2

Puren

 

2

Ampere detector

1

Puren

Can detect Cu2 +, Zn2 +, Pb2 +, Cd2 +

3

High-pressure stratospheric pump

2

From Germany

40Mpa
endurable

4

Six-way injection valve

2

From USA or Japan

Stainless steel, 60Mpa endurable
PEEK, 35 Mpa endurable

5

Flowing pipe

2

Imported

 

6

Anion separation column

1

Original Shodex from Japan

Can analyze F- , Br-,CI-, SO42-, NO3-, NO2-, HPO42-, BrO3-, bromate, ClO3-, ClO2- etc. at one time

7

Anion automatically renewable Suppressor

1

Puren

automatically recycling with the eluent waste

8

Cation separation column

1

Imported

can detect Li+,Na+,NH4+,K+ ,Ca2+,Mg2+,Sr2+,Ba2+ etc. at one time

9

Dual system workstation

1

Puren

 

10

Accessories

1 set

Puren

 

 

2. Configuration of primary hardware

2.1 Conductivity Detector
Precise 5-electrod conductivity detector: main technical performance
5-electrod Conductivity pool: 316 stainless steel ring deactivated electrode, pool size ≤ 1.2ul. With electronic thermostat, temperature accuracy: 5 ~ 50 ºC ± 0.05 ºC
Resolution: not less than 1 / 20000 (≤ 0.025ns)
Baseline noise: less than 0.6% Fs
Baseline drift: less than ± 2.0% Fs
Range: 0 ~ 3500us. Select files with manual and automatic functions.
Output Voltage: 0 ~ 1000mv.
Automatic zero adjustment range:-1000mv ~ +1000 mv.
Suppressor current: 0 ~ 150mA. Increments 1mA, set by the user on the screen.
Can analyze various types of inorganic anions, organic acids, alkali metal, alkaline earth metals, ammonium and quaternary ammonium plasma

2.2 The high-pressure infusion pump 
The machine is microprocessor-controlled dual-piston reciprocating pump, equipped on the fluid path with a buffer and pressure sensors which reduce the pump pulse to a minimum level. Advanced sealing technology enables the pump to work at higher pressure.

Pressure range

0-42.0MPa(stainless iron,ceramic-lined, steel lined with titanium)0~35MPa(PEEK)

Flow range

0.001-9.999mL/min

Flow accuracy

RSD<0.1%

Flow error

<±0.5%

Pressure sensor

Pressure display accuracy: 0.1Mpa

Over-pressure protection

When working pressure is above or below the upper limit or lower limit set, the pump will turn itself off and set the alarm

Material of pump and flow path

PEEK,stainless iron,ceramic-lined, steel lined with titanium( up to the user's choice)

Origin

Germany, the USA, China

2.3 Flow system
2.4Chromatographic column
2.5 Chromatographic column and conductivity pool thermostatic system
2.6 Chromatographic Workstation
2.7Ampere detector: (optional according to customer's requirements, not included in the above quote)

Four kinds of detection methods: DC amps, pulsed amperometric, amperometric, differential pulse voltammetry. By way of flow path or flow injection and the selection of suitable working electrode, the above four methods of measurement can be achieved. Apply to detection of anions (like iodine, sulfur, cyanide), cations( like lead, copper, zinc, cadmium) and organic.

Detection range: 1μg/L-1mg/L 
Detection limit: I- 5ppb,S2- 5 ppb,CN- 5 ppb,Cu2+ 0.5 ppb,Zn2+ 1 ppb,Pb2+ 0.2 ppb,Cd2+ 0.1 ppb

3. Instrument peripherals configuration (self-selection by the customer, prices are not included in the above quote)

3.1 Computer
3.1.1 role: to assist the PIC-10-type halogen dedicated tester for data processing
3.1.2 Configuration: Operating System Configuration: OS - Windows 2000/XP
3.1.3 Memory: 512M
3.1.4 Display Monitor: 17 "SVGA LCD
3.1.5 Hard disk HD: 80G or more
3.1.6 CD-ROM DVD-ROM: 24X or more
3.1.7 CPU: P4 2.6

3.2 Color Inkjet Printers
3.2.1 Role: output the results from the computer.

4. Test spectra:

 

Order

Remaining time

Name

Density

Peak area

Peak Seperation

Theoretical plate number

1

6.207

F

1.0000

532199

8.26

4492

2

9.521

BrO3

5.0000

343348

2.34

8232

3

10.501

Cl

2.0000

736985

6.21

10849

4

13.323

NO2

4.0000

791700

7.66

11735

5

17.483

Br

6.0000

933260

5.29

14697

6

20.848

NO3

6.0000

1221725

7.88

15243

7

26.863

HPO4

8.0000

532169

5.30

16871

8

31.571

SO4

8.0000

2139946

0.00

18808

Total 45.0000 7231332